9187 sc Chlorine Dioxide amperometric analyser

9187 sc Chlorine Dioxide amperometric analyser
Nr. produs: LXV434.99.00001
Preț unitar Contact
Expediere în 1 săptămână

Includes a selective membrane which avoids interference from Chlorine

Stable measurements thanks to the flow-through cell

Easily installed premounted flow-through system

Minimal maintenance thanks to automatic cleaning

Compatible with multi-sensor, multi-parameter digital controllers

Specificaţii

Acuratete: 5% or ±10 ppb ClO2, whichever is greater
Carcasă impermeabilă (IP) : IP66 / NEMA 4X
Condiții de depozitare: -20 °C - 60 °C
Condiții de operare: 0 - 45 °C
Debit: 14 L/h (200 - 250 mL/min) auto-regulated by flow through cell
Domeniu de măsurare: 0 - 2 mg/L ClO2
Garanţie: 24 luni
Greutate: 6,5 kg
Iesire proba: 0.5" inner diameter
Inaltime: 270 mm
Interferente: None
Interval de calibrare: 2 luni
Interval de intretinere: 6 months for membrane and electrolyte (measurement cell)
Interval de masurare: Continuous
Interval de presiune: 0.1 - 2 bar in flow cell
Intrare proba: 0.25" outer diameter
Latime: 250 mm
Limita de detecţie: 0.01 mg/L ClO2
Metoda de calibrare: Zero Calibration: Electrically or with ozone-free water
Calibration: Comparison of lab method with process sample
Modalitate de montaj: Flat, vertical surface (panel, stand, etc.)
Parametru: Chlorine dioxide
Principiu de masurare: Amperometric/Membrane (electrode, membrane, electrolyte)
Standard deviation: 1.5 %
Temperatura probă: 2 - 45 °C
Temperature compensation: Automatic over sample temperature range
  Automatic over sample temperature range
Timp de raspuns - 20 °C: 90% in less than 90 seconds
Umiditate relativa: 0 - 90% non-condensing